"System Error" when creating an A2A application

Prev Next

PAM Core displays System Error when creating an application in the A2A module.

Symptom

  • When saving a new application in the A2A module, with OAuth 1.0 or OAuth 2.0, the system displays System Error.
  • The application is not created.

Solution

Alert

Do not restart the appliance or its services before applying the fix. Restarting does not solve the problem and makes the failure worse.

  1. Apply the fix described in Segura® maintenance script for on-prem customers.
  2. Create the application again.

Existing A2A applications keep working: token issuance and credential lookup through the API are not affected.

For more information

If you are still having trouble, open a ticket with Segura® support using code SOP 140926.